Author

Author Type

Graduate Student

Date of Award

2017

Document Type

Thesis

Publication Status

Version of Record

Submission Date

October 2026

Thesis/Dissertation Advisor [Chair]

Kalantzis, Georgios

Abstract

This research demonstrates that a 3D printed bolus can be customized for electron radiation therapy. Both extruder and powder based printers were used, along with, paraffin wax, super stuff, and H20. The plan dose coverage and conformity for the planning target volume (PTV), was such that the distal side of the PTV was covered by the 90% isodose line. The structure is read, and converted into an STL file. The file is sent to a slicer to print. The object was filled with parafin wax, superstuff or water and sealed. Materials Hounsfield units were analyzed, along with the structure stability. This method is evaluated by scanning the 3D printed bolus. The dose conformity is improved compared to that with no bolus. By generating a patient specific 3D printed bolus there is an in improvement in conformity of the prescription isodose surface while sparing immediately adjacent normal tissues.

Extent

62 p.

Comments

Includes bibliography.|Thesis (M.S.)--Florida Atlantic University, 2017.|FAU Electronic Theses and Dissertations Collection|Includes bibliography.

Identifier

FA00005943

Format

pdf

Share

COinS