Date of Award
2003
Document Type
Thesis
Publication Status
Version of Record
Submission Date
October 2026
Thesis/Dissertation Advisor [Chair]
Hartt, William H.
Abstract
Two models for pipeline bracelet anodes depletion with time were analyzed: one with uniform corrosion and the other with localized corrosion. The potential of the pipeline was determined to become more positive with time due to corrosion of the anode. The pipeline protected by the anode with localized corrosion had more a positive potential than the one protected by the anode with uniform corrosion. A method based upon the equations of Sunde was developed for determining resistance of linear and rectangular anode arrays. Accuracy of this approach was evaluated using Boundary Element Modeling (BEM). The difference between the two methods was defined as Error. A corrected function of Sunde's equation was developed in order to get a more accurate resistance of a 1 x N anode array. The influence on resistance of a M x N (M < N) anode array of anode size, separation distance and array number was analyzed. Error increased with increasing anode size and decreased with increasing number of anodes and separation distance. The application and limitations of commonly used anode resistance formulas are discussed.
Extent
73 p.
Recommended Citation
Zhang, Xiaolin., "Modeling of bracelet anodes and anode arrays for pipeline CP systems" (2003). Electronic Theses and Dissertations 2000 - 2009. 574.
https://digitalcommons.fau.edu/etd_general_5/574
Identifier
FADT13087
Comments
College of Engineering and Computer Science|FAU Electronic Theses and Dissertations Collection|Thesis (M.S.)--Florida Atlantic University, 2003.|College of Engineering and Computer Science