Author

Author Type

Graduate Student

Date of Award

2023

Document Type

Thesis

Publication Status

Version of Record

Submission Date

October 2026

Thesis/Dissertation Advisor [Chair]

Pella, Silvia

Thesis/Dissertation Co-Chair

Theodora Leventouri, Theodora Leventouri,

Abstract

Dose uniformity in the Planning Target Volume (PTV) can induce a higher-than-expected dose distribution in the nearby critical organs. The goal of this study is to evaluate the influence of the Planning Target volume dose uniformity on the surrounding critical organs (OAR). Ten cases of anonymized patients’ data were selected for our study including: Breast cancer, Brain cancer, Head and Neck cancer, Lung and Prostate calculations of Conformity indices, Biological Effective Doses (BED), Tumor Control Probability (TCP) and Normal Tissue Complication Probability (NTCP) were used to calculate the dose distribution in PTV as well as the dose delivered to the surrounding critical organs of each PTV. We assume that the tumors PTVs have homogeneous density as well as the surrounding normal tissue. Conformity indices (CI) for Breast (PTV) are between 1.8 – 1.9, for Brain (PTV) are between 1.6 – 2.0, for Lungs are 1.5 – 1.6, for Prostate are between 0.4 – 0.5, for Head and Neck are 0.3 – 0.4. Dose uniformity in all the PTVs is 1.089 which is a good indication of the quality of treatment delivered to the tumor. TCP is averaging of value of 87.94 and NTCP is 3.4445.

Extent

59 p.

Comments

Includes bibliography.|Thesis (PSM)--Florida Atlantic University, 2023.|FAU Electronic Theses and Dissertations Collection|Includes bibliography.

Identifier

FA00014339

Format

pdf

Share