Date of Award
2017
Document Type
Thesis
Publication Status
Version of Record
Submission Date
October 2026
Thesis/Dissertation Advisor [Chair]
Presuel-Moreno, Francisco
Abstract
Flexible fillers has recently been implemented as corrosion protection for post-tensioning tendons used in bridge structures in Florida. There are two different explanations why corrosion could take place: 1. water is able to reach the steel 2. Microbiologica l ly Influenced Corrosion. The aim of this research is to evaluate corrosion protection effectiveness of five differe nt microcrystalline waxes under different environmental conditions. Specimens tested ranged from 7-wire steel strands to single wires (12-16 cm). Another aim is the appraisal of wax degradation by fungi species. Single wires coated with each of the investigated protection materials, were sprayed with suspensions of three different fungi species and a mix of them. For single wires, independent of the environmental condition the specimen with more corrosion was Nontribos, as well as the filler coated wires contaminated with Fungi. Fungi species investigated were able to utilize the waxes as carbon source and caused differe nt extents of MIC.
Extent
105 p.
Recommended Citation
Castaneda, Carlos F., "Flexible Filler Corrosion Protection of Unbonded Post-Tension Tendons" (2017). Electronic Theses and Dissertations 2010 - 2019. 1697.
https://digitalcommons.fau.edu/etd_general_6/1697
Identifier
FA00004924
Comments
Includes bibliography.|Thesis (M.S.)--Florida Atlantic University, 2017.|FAU Electronic Theses and Dissertations Collection|Includes bibliography.